Job Created: 06/13/22
Job Number: VEC2203 Job Name: V-2330
Job Notes: 301 High st. Dug up main which was 6’ deep, had to use shoring to put tee on, trenched service in, connected everything, moved meter outside, and when tested couldn’t relight due to a no good test on house line, set meter, locked setting off and called in, had 3 soft surface spot holes.
SAP Workorder Number: 102514464
 
Foreman Name:John Greene
Work Dates: 06/10/22 - 06/10/22
Item - Description Item Qty Item UOM
3013254 - Svc: 1-75 ft short side - with main 1 EA
3013389 - Fuel Line: Customer Fuel Line greater than 3 feet, less than or equal to 2" 9 FT
3013392 - Mtr Mvot: Single Meter Moveout / Relocation w/ up to 3' of Fuel Line Relocation 1 EA
3013416 - Combo Dig/Backfill: Spot Holes - soft surface (to ensure separation of facilities during boring activities) 3 EA
3013442 - RETIRE STEEL SERVICE-SAME HOLE =<2" 1 EA
3014620 - Combo Dig/Backfill: Extra depth-bell hole (5-10') 50 SQFT/FT
Extra Service Items:


THIS ORDER IS: APPROVED